Hi,

Has anyone encountered the problem while generating the valor output. I am getting the following error when i try to Begin translation

eif_cadence-583003-Error translating input record.

Also after choosing ODB++ from the PCB Editor it prompts me to extract net impedance average. Is it required? wht is the effect on the manufacturing data.

Thnx

 

Hello

Check your artwork settings (Manufacture - Artwork) and make sure you can generate artworks the old fashioned way. Normal settings are RS274X. Once these are all set you should be able to generate your ODB++ file. In regard to net impedance average will export the net impedance average. Valor has the ability to check some of this stuff. If you don't use it then don't set it.

Steve