现象:在/var/adm/messages中出现以下信息:
Aug 1 10:45:21 imcdb02 scsi: [ID 107833 kern.warning] WARNING: /sbus@a,0/QLGC,isp@2,10000/st@3,0 (st10):
Aug 1 10:45:21 imcdb02 Error for Command: space Error Level: Fatal
Aug 1 10:45:21 imcdb02 scsi: [ID 107833 kern.notice] Requested Block: 1 Error Block: 1
Aug 1 10:45:21 imcdb02 scsi: [ID 107833 kern.notice] Vendor: QUANTUM Serial Number: 0350
Aug 1 10:45:21 imcdb02 scsi: [ID 107833 kern.notice] Sense Key: Media Error
Aug 1 10:45:21 imcdb02 scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0x0
Aug 1 10:45:30 imcdb02 bptm[4206]: [ID 954929 daemon.warning] TapeAlert Code: 0x03, Type: Warning, Flag: HARD ERROR,
from drive QUANTUM.DLT7000.001 (index 1), Media Id ECG877
Aug 1 10:45:30 imcdb02 bptm[4206]: [ID 627995 daemon.crit] TapeAlert Code: 0x05, Type: Critical, Flag: READ FAILURE,
from drive QUANTUM.DLT7000.001 (index 1), Media Id ECG877
由此推断ID为ECG877的磁带损坏.需要更换.
操作步骤:
1. 将坏磁带过期
2. 将坏带取出,并放入新磁带
3. 在备份主机上检查新磁带信息
4. 在NBU的media中,找新添加的磁带
5. inventory robot新带
6. 在备份主机上查看是否成功发现新磁带号
7. NBU中将新磁带更换pool
具体方法:
1. 将坏磁带过期
bpexpdate -m ECG877 -d 0
2. 将坏带取出,并将新磁带放入
在带库中操作.先将损坏的磁带取出(该例为ECG877)然后将新磁带(该例为ECG872)放入带库中.
有两种方法:
a) 在前面板中操作,使用机械臂将磁带取出.
b) 将带库设置为offline状态,并关机,打开前面板,手动找到该磁带,将磁带取出,放入新磁带,关面板,开机后,带机会自动扫描整个带库,新磁带信息将被记录到带库的数据库中.
3. 在备份主机上检查新磁带信息
cd /usr/openv/netbackup/bin/goodies/
./available_media
会发现在列表中的磁带信息是旧的磁带信息,需要更新.即:与带库的数据库信息同步.
4. 在NBU中将media信息更新
进入media中,找到ECG877磁带,右击,选Inventory robot后,有两步操作
a) 在右上角选show contents然后start(查看相关信息)
b) 在右上角选update volume configuration然后start(与带库的数据库同步磁带信息)
5. 在备份主机上查看并确认相关信息
正常情况会是在默认的pool中出现该磁带的信息,并且该磁带是available.
6. 在NBU中修改新磁带的pool信息.将新磁带移到指定的pool中
在media中双机该磁带,在volume pool中选new pool,在右边选择需要指定的pool.