RAD7 Opening
Version 5.1.2 workspaces issues
Below are a number of consideration with regards to opening workspaces that had been created in WebSphere Development Studio Client for iSeries versions prior to 7.0.
Note: Issues below should not prevent the projects from running, either prior to or after converting the project.
Issue |
Solution |
The project cannot be built and messages such as the following are reported in the Problems view: Project XXXX is missing required library: C:\Program Files\IBM\SDP70\jre\lib\rt.jar Unbound classpath container: com.ibm.etools.portal.tools.PORTAL_CLASSPATH_CONTAINER in project XXXX |
You need to set a target server for the project. Right-click WebFacing project > Properties > Targeted Runtimes in the Navigator view. This is the method for version 7.0. In V5.1.2.x, it was optional to set a target server. You should be able to get rid of all the JSP validator errors by setting each project to target a Websphere Application Server V5.1 or greate |