The device paths shown for each system type below are how Solaris recognizes the device. At the Open Boot PROM (OBP), the device name may be slightly different. Typically, the OBP uses `disk' and 'cdrom' aliases for the boot disk and cdrom drive, where Solaris may use a different name/alias for the same device. The overall device path is the same for both OBP and Solaris, the difference is seen at the device position at the end of the path.
Ultra 30, NETRA t 1100
PCI Slot 1 /pci@1f,2000/@1,* 33/66mhz-32/64bit-3.3V
PCI Slot 2 /pci@1f,4000/@2,* 33mhz-32/64bit-5V
PCI Slot 3 /pci@1f,4000/@4,* 33mhz-32/64bit-5V
PCI Slot 4 /pci@1f,4000/@5,* 33mhz-32/64bit-5V
Disk 1
CDROM
External SCSI Port /pci@1f,4000/scsi@3,1/>
Ultra 60, 220R, NETRA t 1120/1125
PCI Slot 1 /pci@1f,2000/@1,* 33/66mhz - 32/64bit – 3.3V
PCI Slot 2 /pci@1f,4000/@2,* 33mhz-32/64bit-5V
PCI Slot 3 /pci@1f,4000/@4,* 33mhz-32/64bit-5V
PCI Slot 4 /pci@1f,4000/@5,* 33mhz-32/64bit-5V
Disk 1
CDROM
External SCSI Port /pci@1f,4000/scsi@3,1/>
Ultra 80, 420R, NETRA t 1400/1405
PCI Slot 1 /pci@1f,2000/@1,* 33/66mhz - 32/64bit – 3.3V
PCI Slot 2 /pci@1f,4000/@4,* 33mhz-32/64bit-5V
PCI Slot 3 /pci@1f,4000/@2,* 33mhz-32/64bit-5V
PCI Slot 4 /pci@1f,4000/@5,* 33mhz-32/64bit-5V
Disk 1
CDROM
External SCSI Port /pci@1f,4000/scsi@3,1/>
Ultra Enterprise 250
PCI Slot 0 /pci@1f,4000/@5,* 33mhz-32/64bit-5V
PCI Slot 1 /pci@1f,4000/@4,* 33mhz-32/64bit-5V
PCI Slot 2 /pci@1f,4000/@2,* 33mhz-32/64bit-5V
PCI Slot 3 /pci@1f,2000/@1,* 33/66mhz-32/64bit-3.3V
Disk 0 (t0)
Disk 1 (t8
Disk 2 (t9)
Disk 3 (t10)
Disk 4 (t11)
Disk 5 (t12)
CDROM
External SCSI Port /pci@1f,4000/scsi@3,1/>
Ultra Enterprise 450
PCI Slot 1 /pci@6,4000/@4,* 33mhz-32/64bit-5V
PCI Slot 2 /pci@6,4000/@3,* 33mhz-32/64bit-5V
PCI Slot 3 /pci@6,4000/@2,* 33mhz-32/64bit-5V
PCI Slot 4 /pci@6,2000/@1,* 33/66mhz-32/64bit-3.3V
PCI Slot 5 /pci@1f,2000/@1,* 33/66mhz-32/64bit-3.3V
PCI Slot 6 /pci@4,2000/@1,* 33/66mhz-32/64bit-3.3V
PCI Slot 7 /pci@4,4000/@4,* 33mhz-32/64bit-5V
PCI Slot 8 /pci@4,4000/@3,* 33mhz-32bit-5V
PCI Slot 9 /pci@4,4000/@2,* 33mhz-32bit-5V
PCI Slot 10 /pci@1f,4000/@4,* 33mhz-32bit-5V
External SCSI Port /pci@1f,4000/scsi@2/>
Internal scsi
disk 1
disk 2
disk 3
disk 4
CDROM
Note: see Infodoc# 16735 for useful information about setting the OBP parameter disk-led-assoc variable to easily translate device paths to internal disk slot numbers in a UE450.
Sun Blade 100
PCI Slot 1 /pci@1f,0/pci@5/@2,* 33mhz-32bit-5V
PCI slot 2 /pci@1f,0/pci@5/@1,* 33mhz-32bit-5V
PCI Solt 3 /pci@1f,0/pci@5/@0,* 33mhz-32bit-5V
primary ide master (default boot)
primary ide slave /pci@1f,0/ide@d/@1,0 (default cdrom)
secondary ide master
secondary ide slave /pci@1f,0/ide@d/@3,0
environmental monitor &
card reader >
proms device>
internal graphics
USB ports device>
Sun Blade 150
PCI Slot 1 /pci@1f,0/@2,* 33mhz-32bit-5V
PCI slot 2 /pci@1f,0/@1,* 33mhz-32bit-5V
PCI Solt 3 /pci@1f,0/@3,* 33mhz-32bit-5V
primary ide master (default boot)
primary ide slave /pci@1f,0/ide@d/@1,0 (default cdrom)
secondary ide master
secondary ide slave /pci@1f,0/ide@d/@3,0
environmental monitor &
card reader >
proms device>
Internal graphics
USB ports device>
Sun Blade 1000/2000, Sun Fire 280R, Netra 20
PCI Slot 1 ,* 33/66mhz-32/64bit-3.3V
PCI Slot 2 ,* 33mhz-32/64bit-5V
PCI Slot 3 ,* 33mhz-32/64bit-5V
PCI Slot 4 ,* 33mhz-32/64bit-5V
Internal Drives >
Internal SCSI bus /pci@8,700000/scsi@6/>
DVD/CDROM
Tape Drive
External FCAL /pci@8,600000/SUNW,glc@4/fp@0,8/>
External SCSI Port /pci@8,700000/scsi@6,1/>
External USB /pci@8,700000/usb@5,3/>
Sun Fire v120 / Netra 120
PCI slot 0 /pci@1f,0/pci@1,1/@1,* 33mhz-32bit-5V
disk 1
disk 2
CDROM
Network 1
Network 2
Sun Fire v210
PCI Slot 0 /pci@1d,700000/@1,* 33/66mhz-32/64bit-3.3V
Internal SCSI bus
disk 1
disk 2
External SCSI bus
DVD Drive
Network 0
Network 1
Network 2
Network 3
pcisch-0 -> PCI2B
pcisch-1 -> PCI2A
pcisch-2 -> PCI1A
pcisch-3 -> PCI2A
Sun Fire v240
PCI Slot 0 /pci@1d,700000/@1,* 33/66mhz-32/64bit-3.3V
PCI Slot 1 /pci@1e,600000/@3,* 33mhz-32/64bit-5V
PCI Slot 2 /pci@1e,600000/@2,* 33mhz-32/64bit-5V
disk 1
disk 2
disk 3
disk 4
External SCSI bus
DVD Drive
Network 0
Network 1
Network 2
Network 3
pcisch-0 -> PCI2B
pcisch-1 -> PCI2A
pcisch-2 -> PCI1A
pcisch-3 -> PCI2A
Sun Fire v440
PCI Slot 0 /pci@1e,600000/@2,* 33mhz-32/64bit-5V
PCI Slot 1 /pci@1e,600000/@3,* 33mhz-32/64bit-5V
PCI Slot 2 /pci@1d,700000/@2,* 33/66mhz-32/64bit-3.3V
CI Slot 3 /pci@1e,600000/@4,* 33mhz-32/64bit-5V
PCI Slot 4 /pci@1d,700000/@1,* 33/66mhz-32/64bit-3.3V
PCI Slot 5 /pci@1c,600000/@1,* 33/66mhz-32/64bit-3.3V
DVD/CDROM
disk 1
disk 2
disk 3
disk 4
Network (CE0)
Network (CE1)
TTYA ALOM
TTYB
Sun Fire v480
PCI Slot 0 /pci@8,600000/@1,* 33/66mhz-32/64bit-3.3V
PCI Slot 1 /pci@8,600000/@2,* 33/66mhz-32/64bit-3.3V
PCI Slot 2 /pci@8,700000/@2,* 33mhz-32/64bit-5V
PCI Slot 3 /pci@8,700000/@3,* 33mhz-32/64bit-5V
PCI Slot 4 /pci@8,700000/@4,* 33mhz-32/64bit-5V
PCI Slot 5 /pci@8,700000/@5,* 33mhz-32/64bit-5V
disk 1
disk 2
DVD/CDROM
Network 1
Network 2
EBUS
USB
Sun Fire V880
PCI Slot 0 /pci@8,700000/@5,* 33mhz-32/64bit-5V
PCI Slot 1 /pci@8,700000/@4,* 33mhz-32/64bit-5V
PCI Slot 2 /pci@8,700000/@3,* 33mhz-32/64bit-5V
PCI Slot 3 /pci@8,700000/@2,* 33mhz-32/64bit-5V
PCI Slot 4 /pci@9,700000/@4,* 33mhz-32/64bit-5V
PCI Slot 5 /pci@9,700000/@3,* 33mhz-32/64bit-5V
PCI Slot 6 /pci@9,700000/@2,* 33mhz-32/64bit-5V
PCI Slot 7 /pci@9,600000/@2,* 33/66mhz-32/64bit-3.3V
PCI Slot 8 /pci@9,600000/@1,* 33/66mhz-32/64bit-3.3V
Onboard FCALloopA
loopB
EBUS /pci@9,700000/ebus@1/>
Network 1 (GE)
Network 2 (hme)
USB /pci@9,700000/usb@1,3/>
Sun Fire 1280
PCI Slot 0 /ssm@0,0/pci@18,700000/@1,* 33mhz-32/64bit-5V
PCI Slot 1 /ssm@0,0/pci@18,700000/@2,* 33mhz-32/64bit-5V
PCI Slot 2 /ssm@0,0/pci@19,700000/@1,* 33mhz-32/64bit-5V
PCI Slot 3 /ssm@0,0/pci@19,700000/@2,* 33mhz-32/64bit-5V
PCI Slot 4 /ssm@0,0/pci@19,700000/@3,* 33mhz-32/64bit-5V
PCI Slot 5 /ssm@0,0/pci@18,600000/@1,* 33/66mhz-32/64bit-3.3V
disk 1
disk 2
CDROM
Tape Drive
Network 1
Network 2
Dual PCI SCSI cards:
If you have such a card installed in your system, the device path will look like the following.
Lets say, the card is installed in a Enterprise 450 machine:
PCI Slot 1 /pci@6,4000/@4,* <- this refers to the first VHDCI scsi connector
/pci@6,4000/@4,1 <- this refers to the second VHDCI scsi connector
When the card is installed in its pci slot:
Internal:
- the left connector (close to the back of the system) is controller @4 (first controller)
- the right connector is controller @4,1 (second controller)
External (when standing at the back of the system):
- the left connector is controller @4
- the right connecter is controller @4,1
Internal Only Top
This document obsoletes the following Infodocs:
- 18931 How to read Enterprise [TM] 450 device path and correlate it to PCI slot
- 18365 Internal addresses of Disk drives, tape and CD-ROM installed in a Enterprise [TM]250
- 72135 Sun Fire[TM] V210/V240 Device Path Breakout
Added the SunBlade 2500 to the list, although it's GA (general availability) date is 12/03/03. For this I
put it here for the moment being.
Sun Blade 2500
PCI Slot #0 /pci@1e,600000/@2,* 33mhz-32/64bit-5V
PCI Slot #1 /pci@1e,600000/@3,* 33mhz-32/64bit-5V
PCI Slot #2 /pci@1d,700000/@2,* 33/66mhz–32/64bit–3.3V
PCI Slot #3 /pci@1e,600000/@4,* 33/66mhz–32/64bit–3.3V
PCI Slot #4 /pci@1d,700000/@1,* 33mhz-32/64bit-5V
PCI Slot #5 /pci@1c,600000/@1,* 33/66mhz–32/64bit–3.3V
DVD/CDROM
Internal Drives
Ultra320 SCSI
disk 1
disk 2
TTYA ALOM
TTYB
Network (CE0)
This infodoc is updated by Georges Riahi
Contributers are: Mick Tabor - Eric D. Larson – John Silva – Olly Sharwood
阅读(977) | 评论(0) | 转发(0) |