一、A500开机点不亮,报错SOURCE: 6 = platform  SOURCE DETAIL: 1 = cabinet   SOURCE ID

 

GSP>sl

 

SOURCE: 6 = platform  SOURCE DETAIL: 1 = cabinet   SOURCE ID: 0

************* SYSTEM ALERT **************

SYSTEM NAME: xxx

DATE: 01/01/1970 TIME: 00:19:33

ALERT LEVEL: 14 = Fatal power or environmental problem prevents operation

 

REASON FOR ALERT

SOURCE: 6 = platform

SOURCE DETAIL: 1 = cabinet   SOURCE ID: 0

PROBLEM DETAIL: 7 = unexpected

 

GSP> pc on

  The system did not respond to the Power-On command.

  Turn the system power switch Off and On again to reset the system.

 

 

故障原因及解决方法

 

在运输过程中机箱上外壳变形,硬盘旁边有个小洞,里面一个铁片需要顶进去,否则机器无法启动。更换变形的机箱上外壳机壳即可。

 

 

 

 

二、A500 sl检查报错SOURCE: 8 = I/O SOURCE DETAIL: 3 = local bus adapter   SOURCE ID: FF

 

 

故障原因及解决方法

 

I/O card cage松动,在主板上没有插紧。重新插紧即可。

 

 

 

三、后面板警示灯琥珀色闪烁

 

 

 

故障原因及解决方法

 

经过其他检查诊断没有故障。

 

有的时候,如果直接关闭电源等误操作,重启后警示灯会琥珀色闪烁。

 

GSP>sl 查看日志后  警示灯即熄灭。即这里警示灯闪烁只是提醒你查看一下GSP日志。

阅读(1559) | 评论(0) | 转发(0) |