2014年(381)
分类: NOSQL
2014-07-09 17:15:56
1, the thermostat "Thermostat disc" installation,
temperature control is possible snapping entire surface temperature to achieve
accurate temperature control purposes
2, the installation can not be a sense
of pressure tube deformation temperature, so as not to affect its performance
3 Do not allow conductive or conductive material into the gas thermostat
"Thermostat disc" or contaminated surfaces thermostat to avoid
affecting the electrical insulation properties
4, the electrical switch box
ceramic pieces gently to avoid damage
5, the capillary bending radius not
less than 5mm.
"Thermostat disc" Purchase Description
1, shaft sizes and starting angle of rotation required by customer demand to
set
2, disconnect the temperature characteristic curve of its finished
products in accordance with customer needs and thermostat match test may be
3, a variety of terminal sizes and orientation, capillary tube length and
jacket can be arbitrarily chosen with the customer
4, in order to facilitate
customers to install the thermostat "", the thermostat can be welded in different diameters bulb