今天客户的IBM小机报错:BD797922
LABEL: SSA_ENCL_ERR1
IDENTIFIER: BD797922
Date/Time: Fri Jan 22 16:00:11 BEIS
Sequence Number: 1123
Machine Id: 0050138B4C00
Node Id: myin2
Class: H
Type: PERM
Resource Name: enclosure0
Resource Class: container
Resource Type: ses
Location: 00-00-4D5C
VPD:
Part Number.................9L1850
Serial Number...............292C4D5C
EC Level....................000000R000
Manufacturer................IBM053
ROS Level and ID............0020
Device Specific.(Z0)........DISPLAY=4D5C
Device Specific.(Z1)........BYPASS1_16= 09L5580
Device Specific.(Z2)........BYPASS4_5= 09L5580
Device Specific.(Z3)........BYPASS8_9= 09L5580
Device Specific.(Z4)........BYPASS12_13= 09L5580
Device Specific.(Z5)........FAN1=09L2794
Device Specific.(Z6)........FAN2=09L2794
Device Specific.(Z7)........FAN3=09L2794
Device Specific.(Z8)........PSU1=09L4299
Device Specific.(Z9)........PSU2=09L4299
Device Specific.(ZA)........CTRL= 27H0708
Device Specific.(ZB)........OPERATOR= 08L7924
Description
SUBSYSTEM FAILURE
Probable Causes
SUBSYSTEM
Failure Causes
SUBSYSTEM
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0802 3200 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
确定是7133存储的问题,后检查7133存储的面板发现面板报FAN2错误,故确定是第二个风扇的问题。
但是还没有到客户处进行进一步检查维护,待明天去了再说吧
阅读(737) | 评论(0) | 转发(0) |