Chinaunix首页 | 论坛 | 博客
  • 博客访问: 430543
  • 博文数量: 286
  • 博客积分: 6011
  • 博客等级: 准将
  • 技术积分: 3010
  • 用 户 组: 普通用户
  • 注册时间: 2008-08-06 10:08
文章分类

全部博文(286)

文章存档

2011年(1)

2009年(285)

我的朋友

分类: 系统运维

2009-06-01 17:08:07

IC info: MAC-I     = 0xd2dce404
         RRC-SN    = 3
         Direction = 1
         Length    = 272 bits

    DL-DCCH-Message {
     integrityCheckInfo {
      messageAuthenticationCode '11010010110111001110010000000100'B,
      rrc-MessageSequenceNumber 3
     },
     message measurementControl : later-than-r3 : {
        rrc-TransactionIdentifier 0,
        criticalExtensions later-than-r4 : {
          rrc-TransactionIdentifier-MSP-r6-ext 0,
          criticalExtensions-r5 r6 : {
            measurementControl-r6 {
             measurementIdentity 1,
             measurementCommand setup : intraFrequencyMeasurement : {
                intraFreqCellInfoList {
                 removedIntraFreqCellList removeAllIntraFreqCells : NULL,
                 newIntraFreqCellList {
                  {
                   intraFreqCellID 0,
                   cellInfo {
                    modeSpecificInfo fdd : {
                      primaryCPICH-Info {
                       primaryScramblingCode 111
                      },
                      readSFN-Indicator TRUE,
                      tx-DiversityIndicator FALSE
                     }
                   }
                  },
                  {
                   intraFreqCellID 2,
                   cellInfo {
                    modeSpecificInfo fdd : {
                      primaryCPICH-Info {
                       primaryScramblingCode 122
                      },
                      readSFN-Indicator TRUE,
                      tx-DiversityIndicator FALSE
                     }
                   }
                  }
                 }
                },
                intraFreqMeasQuantity {
                 filterCoefficient fc3,
                 modeSpecificInfo fdd : {
                   intraFreqMeasQuantity-FDD cpich-Ec-N0
                  }
                },
                intraFreqReportingQuantity {
                 activeSetReportingQuantities {
                  dummy noReport,
                  cellIdentity-reportingIndicator FALSE,
                  cellSynchronisationInfoReportingIndicator TRUE,
                  modeSpecificInfo fdd : {
                    cpich-Ec-N0-reportingIndicator TRUE,
                    cpich-RSCP-reportingIndicator TRUE,
                    pathloss-reportingIndicator FALSE
                   }
                 },
                 monitoredSetReportingQuantities {
                  dummy noReport,
                  cellIdentity-reportingIndicator FALSE,
                  cellSynchronisationInfoReportingIndicator TRUE,
                  modeSpecificInfo fdd : {
                    cpich-Ec-N0-reportingIndicator TRUE,
                    cpich-RSCP-reportingIndicator TRUE,
                    pathloss-reportingIndicator FALSE
                   }
                 }
                },
                reportCriteria intraFreqReportingCriteria : {
                  eventCriteriaList {
                   {
                    event e1a : {
                      triggeringCondition monitoredSetCellsOnly,
                      reportingRange 8,
                      w 0,
                      reportDeactivationThreshold t2,
                      reportingAmount ra-Infinity,
                      reportingInterval ri0-5
                     },
                    hysteresis 0,
                    timeToTrigger ttt100,
                    reportingCellStatus allActiveplusMonitoredSet : viactCellsPlus2
                   },
                   {
                    event e1b : {
                      triggeringCondition activeSetCellsOnly,
                      reportingRange 12,
                      w 0
                     },
                    hysteresis 0,
                    timeToTrigger ttt640,
                    reportingCellStatus allActiveplusMonitoredSet : viactCellsPlus2
                   },
                   {
                    event e1c : {
                      replacementActivationThreshold t3,
                      reportingAmount ra-Infinity,
                      reportingInterval ri0-5
                     },
                    hysteresis 4,
                    timeToTrigger ttt100,
                    reportingCellStatus allActiveplusMonitoredSet : viactCellsPlus2
                   }
                  }
                 }
               },
             measurementReportingMode {
              measurementReportTransferMode acknowledgedModeRLC,
              periodicalOrEventTrigger eventTrigger
             }
            },
            v6a0NonCriticalExtensions {
             measurementControl-v6a0ext {
              intraFreqReportingCriteria-1b-r5 {
               periodicReportingInfo-1b {
                reportingAmount ra-Infinity,
                reportingInterval ri0-5
               }
              }
             }
            }
           }
         }
       }
    }
 
阅读(338) | 评论(0) | 转发(0) |
给主人留下些什么吧!~~