*& Report BCALV_TEST_GRID_LAYOUT *
*& *
*&---------------------------------------------------------------------*
*& *
*& *
*&---------------------------------------------------------------------*
report bcalv_test_grid_layout.
types: g_ty_s_sflight type alv_t_t2.
constants: con_sflight type lvc_fname value 'ALV_T_T2'.
*----------------------------------------------------------------------*
* DATA *
*----------------------------------------------------------------------*
include .
include .
type-pools: slis.
class cl_gui_resources definition load.
types: g_ty_t_icon type standard table of icon,
g_ty_t_icont type standard table of icont,
begin of g_ty_s_test,
select_amount type i,
vari_none type char1,
vari_save type char1,
vari_default type char1,
vari_layout type disvariant-variant,
vari_dark type disvariant-variant,
vari_dark_user type syuname,
layo_no_authcheck type char1,
bypassing_buffer type char1,
buffer_active type char1,
current_display type i,
end of g_ty_s_test,
begin of g_ty_s_outtab.
include type g_ty_s_sflight.
types: checkbox type char1,
box type char1,
count type i,
lights type char1,
end of g_ty_s_outtab,
g_ty_t_outtab type table of g_ty_s_outtab.
constants: con_true type char1 value 'X',
con_display_list type i value 1,
con_display_grid type i value 2,
con_display_full type i value 3,
con_dark_on type sy-ucomm value 'DARK_ON',
con_dark_off type sy-ucomm value 'DARK_OFF',
con_exit type sy-ucomm value 'EXIT',
con_canc type sy-ucomm value 'CANC',
con_back type sy-ucomm value 'BACK'.
data: g_okcode type sy-ucomm.
data: gs_test type g_ty_s_test.
data: g_repid type sy-repid.
data: gt_outtab type g_ty_t_outtab,
gr_container_d0100 type ref to cl_gui_custom_container,
gr_grid_d0100 type ref to cl_gui_alv_grid.
*----------------------------------------------------------------------*
* SELECTION-SCREEN *
*----------------------------------------------------------------------*
selection-screen begin of block gen with frame.
parameters:
p_amount type i default 30.
selection-screen end of block gen.
selection-screen begin of block var with frame title text-var.
parameters:
p_var01 radiobutton group save, "BENUTZERSPEZ
p_var02 radiobutton group save, "BENUTZER蹷ERGREIF
p_var03 radiobutton group save, "ALLES
p_var04 radiobutton group save. "KEINE
selection-screen skip.
parameters:
p_var05 as checkbox. "KEINE VERWALTUNG
selection-screen skip.
parameters:
p_var06 as checkbox. "DEFAULT
selection-screen skip.
parameters:
p_var07 like disvariant-variant. "LAYOUT
selection-screen skip.
parameters:
p_var08 as checkbox. "NO AUTHORITY CHECK
selection-screen end of block var.
selection-screen begin of block drk with frame.
parameters:
p_drk01 like disvariant-variant, "LAYOUT DARK
p_drk02 like sy-uname. "USERNAME VARIANT DARK
selection-screen end of block drk.
*----------------------------------------------------------------------*
* AT SELECTION-SCREEN ON VALUE-REQUEST *
*----------------------------------------------------------------------*
at selection-screen on value-request for p_var07.
perform f01_f4_variant changing p_var07.
*----------------------------------------------------------------------*
* START-OF-SELECTION *
*----------------------------------------------------------------------*
start-of-selection.
g_repid = sy-repid.
gs_test-select_amount = p_amount.
case con_true.
when p_var01.
gs_test-vari_save = 'U'.
when p_var02.
gs_test-vari_save = 'X'.
when p_var03.
gs_test-vari_save = 'A'.
when p_var04.
gs_test-vari_save = ' '.
endcase.
gs_test-vari_none = p_var05.
gs_test-vari_default = p_var06.
gs_test-vari_layout = p_var07.
gs_test-layo_no_authcheck = p_var08.
gs_test-vari_dark = p_drk01.
gs_test-vari_dark_user = p_drk02.
gs_test-bypassing_buffer = space.
gs_test-buffer_active = space.
*----------------------------------------------------------------------*
* END-OF-SELECTION *
*----------------------------------------------------------------------*
end-of-selection.
call screen 100.
*&---------------------------------------------------------------------*
*& Module d0100_set_status OUTPUT
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
module d0100_set_status output.
perform d0100_set_status.
endmodule. " d0100_set_status OUTPUT
*&---------------------------------------------------------------------*
*& Module d0100_prepare_container OUTPUT
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
module d0100_prepare_container output.
perform d0100_prepare_container.
endmodule. " d0100_prepare_container OUTPUT
*&---------------------------------------------------------------------*
*& Module d0100_exit INPUT
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
module d0100_exit input.
perform d0100_exit.
endmodule. " d0100_exit INPUT
*&---------------------------------------------------------------------*
*& Module d0100_fcode INPUT
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
module d0100_fcode input.
perform d0100_fcode.
endmodule. " d0100_fcode INPUT
*&---------------------------------------------------------------------*
*& Form d0100_set_status
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
form d0100_set_status .
types: begin of l_ty_s_excl,
func type syucomm,
end of l_ty_s_excl,
l_ty_t_excl type standard table of l_ty_s_excl.
data: lt_excl type l_ty_t_excl.
set pf-status 'D0100' excluding lt_excl.
set titlebar 'D0100'.
endform. " d0100_set_status
*&---------------------------------------------------------------------*
*& Form d0100_prepare_container
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
form d0100_prepare_container .
data: lt_fcat type lvc_t_fcat,
ls_layo type lvc_s_layo,
ls_vari type disvariant,
ls_prnt type lvc_s_prnt,
l_consistency_check type char1.
gs_test-current_display = con_display_grid.
if gr_container_d0100 is initial.
if cl_gui_alv_grid=>offline( ) is initial.
create object gr_container_d0100
exporting container_name = 'D0100_CONTAINER'.
endif.
create object gr_grid_d0100
exporting i_parent = gr_container_d0100.
perform d0100_get_outtab.
perform d0100_set_grid_vari using space changing ls_vari.
perform d0100_set_grid_layo changing ls_layo.
perform d0100_set_grid_fcat changing lt_fcat.
ls_prnt-grpchgedit = con_true.
call method gr_grid_d0100->set_table_for_first_display
exporting
i_buffer_active = gs_test-buffer_active
i_bypassing_buffer = gs_test-bypassing_buffer
i_consistency_check = l_consistency_check
is_variant = ls_vari
i_save = gs_test-vari_save
i_default = gs_test-vari_default
is_layout = ls_layo
is_print = ls_prnt
changing
it_outtab = gt_outtab[]
it_fieldcatalog = lt_fcat.
if gs_test-vari_dark ne space.
perform d0100_set_grid_vari using con_true changing ls_vari.
call method gr_grid_d0100->save_variant_dark
exporting
is_variant = ls_vari.
endif.
endif.
endform. " d0100_prepare_container
*&---------------------------------------------------------------------*
*& Form d0100_exit
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
form d0100_exit .
data: l_okcode like sy-ucomm.
l_okcode = g_okcode.
clear g_okcode.
case l_okcode.
when con_exit or con_back or con_canc.
call method gr_grid_d0100->free.
call method gr_container_d0100->free.
call method cl_gui_cfw=>flush.
clear gr_container_d0100.
clear gr_grid_d0100.
set screen 0.
leave screen.
endcase.
endform. " d0100_exit
*&---------------------------------------------------------------------*
*& Form d0100_fcode
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
form d0100_fcode .
data: l_okcode like sy-ucomm,
ls_selfield type slis_selfield.
l_okcode = g_okcode.
clear g_okcode.
case l_okcode.
when con_exit or con_back or con_canc.
g_okcode = l_okcode.
perform d0100_exit.
when others.
perform f01_alv_event_user_command using l_okcode
ls_selfield.
endcase.
endform. " d0100_fcode
*&---------------------------------------------------------------------*
*& Form d0100_set_grid_vari
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
form d0100_set_grid_vari using i_dark
changing cs_vari type disvariant.
if gs_test-vari_none ne space and i_dark eq space.
exit.
endif.
cs_vari-report = sy-repid.
cs_vari-handle = space.
cs_vari-log_group = space.
cs_vari-username = space.
cs_vari-variant = gs_test-vari_layout.
cs_vari-text = space.
cs_vari-dependvars = space.
if i_dark eq con_true.
cs_vari-variant = gs_test-vari_dark.
cs_vari-username = gs_test-vari_dark_user.
cs_vari-text = cs_vari-variant.
endif.
endform. " d0100_set_grid_vari
*&---------------------------------------------------------------------*
*& Form d0100_set_grid_layo
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
form d0100_set_grid_layo changing cs_layo type lvc_s_layo.
*... ALV-Control: Allgemeine Anzeigeoptionen
cs_layo-stylefname = space.
cs_layo-graphics = space.
cs_layo-frontend = space.
cs_layo-template = space.
*... ALV-Control: Gridcustomizing
cs_layo-grid_title = space.
cs_layo-smalltitle = space.
cs_layo-cwidth_opt = con_true.
cs_layo-zebra = space.
cs_layo-no_colexpd = space.
cs_layo-no_hgridln = space.
cs_layo-no_vgridln = space.
cs_layo-no_rowmark = space.
cs_layo-no_headers = space.
cs_layo-no_merging = space.
cs_layo-no_toolbar = space.
cs_layo-sel_mode = space.
cs_layo-sgl_clk_hd = space.
cs_layo-box_fname = 'BOX'.
*... ALV-Control: Summenoptionen
cs_layo-totals_bef = space.
cs_layo-no_totline = space.
cs_layo-numc_total = space.
cs_layo-no_utsplit = space.
*... ALV-Control: Exceptions
cs_layo-excp_group = space.
cs_layo-excp_fname = 'LIGHTS'.
cs_layo-excp_rolln = space.
cs_layo-excp_conds = space.
cs_layo-excp_led = space.
*... ALV-Control: Steuerung Interaktion
cs_layo-detailinit = space.
cs_layo-detailtitl = space.
cs_layo-keyhot = space.
cs_layo-no_keyfix = space.
cs_layo-no_author = gs_test-layo_no_authcheck.
clear cs_layo-s_dragdrop.
*... ALV-Control: Farben
cs_layo-info_fname = space.
cs_layo-ctab_fname = space.
*... ALV-Control: Eingabef鋒igkeit
cs_layo-edit = space.
cs_layo-edit_mode = space.
cs_layo-no_rowins = space.
cs_layo-no_rowmove = space.
*... ALV-Control: Web-Optionen
cs_layo-weblook = space.
cs_layo-webstyle = space.
cs_layo-webrows = space.
cs_layo-webxwidth = space.
cs_layo-webxheight = space.
endform. " d0100_set_grid_layo
*&---------------------------------------------------------------------*
*& Form d0100_set_grid_fcat
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
form d0100_set_grid_fcat changing ct_fcat type lvc_t_fcat.
call function 'LVC_FIELDCATALOG_MERGE'
exporting
i_buffer_active = gs_test-buffer_active
i_structure_name = con_sflight
i_client_never_display = con_true
i_bypassing_buffer = gs_test-bypassing_buffer
changing
ct_fieldcat = ct_fcat[]
exceptions
inconsistent_interface = 1
program_error = 2
others = 3.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
endif.
endform. " d0100_set_grid_fcat
*&---------------------------------------------------------------------*
*& Form d0100_get_outtab
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
form d0100_get_outtab .
field-symbols: type g_ty_s_outtab.
data: l_excp_mod type i,
l_excp_div type i,
l_excp_amnt type i value 4,
l_excp type i.
if gs_test-select_amount gt 0.
select * from (con_sflight) into corresponding fields
of table gt_outtab up to gs_test-select_amount rows.
endif.
gs_test-select_amount = sy-dbcnt.
loop at gt_outtab assigning .
*... Exception
l_excp_mod = sy-tabix mod l_excp_amnt.
if l_excp_mod eq 0.
l_excp_div = 1.
else.
l_excp_div = 0.
endif.
l_excp = ( l_excp_amnt * l_excp_div ) + l_excp_mod.
if l_excp_amnt eq 4.
subtract 1 from l_excp.
endif.
-lights = l_excp.
endloop.
endform. " d0100_get_outtab
*&---------------------------------------------------------------------*
*& Form f01_f4_variant
*&---------------------------------------------------------------------*
* text
*----------------------------------------------------------------------*
form f01_f4_variant changing c_variant type disvariant-variant.
data: ls_variant type disvariant,
l_exit type char1.
ls_variant-report = sy-repid.
call function 'REUSE_ALV_VARIANT_F4'
exporting
is_variant = ls_variant
i_save = 'A'
* it_default_fieldcat =
importing
e_exit = l_exit
es_variant = ls_variant
exceptions
not_found = 2.
if sy-subrc = 2.
message id sy-msgid type 'S' number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
else.
if l_exit eq space.
c_variant = ls_variant-variant.
endif.
endif.
endform. " f01_f4_variant
*---------------------------------------------------------------------*
* FORM f01_alv_event_pf_status_set
*---------------------------------------------------------------------*
*
*---------------------------------------------------------------------*
form f01_alv_event_pf_status_set using rt_extab type slis_t_extab.
"#EC *
set pf-status 'STANDARD' excluding rt_extab.
set titlebar 'D0100'.
endform. "f01_alv_event_pf_status_set
*---------------------------------------------------------------------*
* FORM f01_alv_event_user_command
*---------------------------------------------------------------------*
*
*---------------------------------------------------------------------*
form f01_alv_event_user_command using r_ucomm like sy-ucomm
rs_selfield type slis_selfield.
"#EC *
data: ls_vari type disvariant,
ls_slis_layo type slis_layout_alv,
lt_slis_fcat type slis_t_fieldcat_alv,
lt_slis_sort type slis_t_sortinfo_alv,
lt_slis_filt type slis_t_filter_alv,
ls_slis_prnt type slis_print_alv,
ls_lvc_layo type lvc_s_layo,
lt_lvc_fcat type lvc_t_fcat,
lt_lvc_sort type lvc_t_sort,
lt_lvc_filt type lvc_t_filt,
ls_lvc_prnt type lvc_s_prnt.
case r_ucomm.
when con_dark_on or con_dark_off.
data: l_active type char1.
case r_ucomm.
when con_dark_on.
l_active = con_true.
when con_dark_off.
l_active = space.
endcase.
call method gr_grid_d0100->save_variant_dark
exporting
i_active = l_active.
when others.
endcase.
check r_ucomm eq 'LIST' or
r_ucomm eq 'FULLSCREEN' or
r_ucomm eq 'GRID'.
case gs_test-current_display.
when con_display_list or con_display_full.
case gs_test-current_display.
when con_display_list.
call function 'REUSE_ALV_LIST_LAYOUT_INFO_GET'
importing
es_layout = ls_slis_layo
et_fieldcat = lt_slis_fcat
et_sort = lt_slis_sort
et_filter = lt_slis_filt
es_variant = ls_vari
exceptions
no_infos = 1
program_error = 2
others = 3.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
endif.
when con_display_full.
call function 'REUSE_ALV_GRID_LAYOUT_INFO_GET'
importing
es_layout = ls_slis_layo
et_fieldcat = lt_slis_fcat
et_sort = lt_slis_sort
et_filter = lt_slis_filt
es_variant = ls_vari
es_print = ls_slis_prnt
exceptions
no_infos = 1
program_error = 2
others = 3.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
endif.
endcase.
call function 'LVC_TRANSFER_FROM_SLIS'
exporting
it_fieldcat_alv = lt_slis_fcat
it_sort_alv = lt_slis_sort
it_filter_alv = lt_slis_filt
is_layout_alv = ls_slis_layo
importing
et_fieldcat_lvc = lt_lvc_fcat
et_sort_lvc = lt_lvc_sort
et_filter_lvc = lt_lvc_filt
es_layout_lvc = ls_lvc_layo
tables
it_data = gt_outtab
exceptions
it_data_missing = 1
others = 2.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
endif.
when con_display_grid.
set screen 0.
call method gr_grid_d0100->get_variant
importing
es_variant = ls_vari.
call method gr_grid_d0100->get_frontend_layout
importing
es_layout = ls_lvc_layo.
call method gr_grid_d0100->get_frontend_fieldcatalog
importing
et_fieldcatalog = lt_lvc_fcat.
call method gr_grid_d0100->get_sort_criteria
importing
et_sort = lt_lvc_sort.
call method gr_grid_d0100->get_frontend_print
importing
es_print = ls_lvc_prnt.
call method gr_grid_d0100->get_filter_criteria
importing
et_filter = lt_lvc_filt.
call function 'LVC_TRANSFER_TO_SLIS'
exporting
it_fieldcat_lvc = lt_lvc_fcat
it_sort_lvc = lt_lvc_sort
it_filter_lvc = lt_lvc_filt
is_layout_lvc = ls_lvc_layo
importing
et_fieldcat_alv = lt_slis_fcat
et_sort_alv = lt_slis_sort
et_filter_alv = lt_slis_filt
es_layout_alv = ls_slis_layo
tables
it_data = gt_outtab
exceptions
it_data_missing = 1
it_fieldcat_lvc_missing = 2
others = 3.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
endif.
endcase.
case r_ucomm.
when 'LIST'.
gs_test-current_display = con_display_list.
call function 'REUSE_ALV_LIST_DISPLAY'
exporting
i_bypassing_buffer = gs_test-bypassing_buffer
i_buffer_active = gs_test-buffer_active
i_callback_program = g_repid
i_callback_pf_status_set = 'F01_ALV_EVENT_PF_STATUS_SET'
i_callback_user_command = 'F01_ALV_EVENT_USER_COMMAND'
is_layout = ls_slis_layo
it_fieldcat = lt_slis_fcat
it_sort = lt_slis_sort
it_filter = lt_slis_filt
i_default = gs_test-vari_default
i_save = gs_test-vari_save
is_variant = ls_vari
is_print = ls_slis_prnt
tables
t_outtab = gt_outtab
exceptions
program_error = 1
others = 2.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
endif.
when 'FULLSCREEN'.
gs_test-current_display = con_display_full.
call function 'REUSE_ALV_GRID_DISPLAY'
exporting
i_bypassing_buffer = gs_test-bypassing_buffer
i_buffer_active = gs_test-buffer_active
i_callback_program = g_repid
i_callback_pf_status_set = 'F01_ALV_EVENT_PF_STATUS_SET'
i_callback_user_command = 'F01_ALV_EVENT_USER_COMMAND'
is_layout = ls_slis_layo
it_fieldcat = lt_slis_fcat
it_sort = lt_slis_sort
it_filter = lt_slis_filt
i_default = gs_test-vari_default
i_save = gs_test-vari_save
is_variant = ls_vari
is_print = ls_slis_prnt
tables
t_outtab = gt_outtab
exceptions
program_error = 1
others = 2.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
endif.
when 'GRID'.
gs_test-current_display = con_display_grid.
if gr_container_d0100 is initial.
create object gr_container_d0100
exporting container_name = 'D0100_CONTAINER'.
create object gr_grid_d0100
exporting i_parent = gr_container_d0100.
endif.
call method gr_grid_d0100->set_table_for_first_display
exporting
i_buffer_active = gs_test-buffer_active
i_bypassing_buffer = gs_test-bypassing_buffer
is_variant = ls_vari
i_save = gs_test-vari_save
i_default = gs_test-vari_default
is_layout = ls_lvc_layo
is_print = ls_lvc_prnt
changing
it_outtab = gt_outtab[]
it_fieldcatalog = lt_lvc_fcat
it_sort = lt_lvc_sort
it_filter = lt_lvc_filt.
call screen 100.
endcase.
rs_selfield-exit = con_true.
endform. "f01_alv_event_user_command