下面是测量数据:
1,2.5V基准测量数据:
供电电压: 测得基准电压:
2.801 2.479
3.002 2.480
3.293 2.485
3.505 2.487
2,1.5V基准测量数据:
供电电压: 测得基准电压:
1.800 1.480
2.002 1.481
2.199 1.482
2.500 1.483
2.708 1.483
2.801 1.483
3.003 1.484
3.299 1.485
3.497 1.487
MSP430F149数据手册中对于VREF的指标:
测量设备和样品:
测试代码:
#include "msp430x14x.h" // Standard Equations
void main(void)
{
unsigned int i;
WDTCTL = WDTPW+WDTHOLD; // Stop watchdog timer
P6SEL = 0x01; // Enable A/D channel A0
// ADC12CTL0 = ADC12ON+SHT0_2+REFON+REF2_5V; // Turn on and set up ADC12,2.5V Internal REF
ADC12CTL0 = ADC12ON+SHT0_2+REFON; // Turn on and set up ADC12,1.5V Internal REF
ADC12CTL1 = SHP; // Use sampling timer
ADC12MCTL0 = SREF_1; // Vr+=Vref+
for ( i=0; i<0x3600; i++) // Delay for reference start-up
{
}
ADC12CTL0 = ENC; // Enable conversions
while (1)
{
ADC12CTL0 = ADC12SC; // Start conversion
while ((ADC12IFG & BIT0)==0);
_NOP(); // SET BREAKPOINT HERE
}
}
总结:
本测试中的MSP430F149的1.5V内部基准负偏了2/150=1.3%左右,2.5V内部基准负偏了2/250=0.8%,作为普通用途基本可以 接受,和AVR系列的内部基准相比要好不少,但是如果应用在高精度测量设备中则1.5V基准有待改进,建议使用更高精度外部电压基准。
注意本测试仅针对本测试样品,本样品为TI提供的免费样品,可能性能上面也会有点不同,请读者针对自己实际使用的样品进行仔细评估,本报告仅提供一个参考值。
LM2825 DC-DC模块提供的直流电压的AC分量经FLUKE 189测量小于1mV。
感谢TI提供免费MSP430F149样品,感谢NSC提供免费LM2825样品。
测试温度:环境温度24度。
由于条件所限本测试未涉及到F149基准的温漂。
此MSP430F149的基准初始精度不是很高,而且随供电电压的变化也有不小的变化,同时温度漂移量也不是很理想,如果选其作为基准需要考虑工作温度范围、工作电压范围等诸多因素。