Chinaunix首页 | 论坛 | 博客
  • 博客访问: 576328
  • 博文数量: 113
  • 博客积分: 3322
  • 博客等级: 少校
  • 技术积分: 1565
  • 用 户 组: 普通用户
  • 注册时间: 2006-01-04 11:38
文章分类

全部博文(113)

文章存档

2012年(21)

2010年(92)

分类:

2010-03-02 10:42:59

安装前准备
修改主机的/etc/hosts文件,增加如下行
X.X.X.X        nbuserver
保证200MB的空间
必须使用root用户安装安装过程


Symantec Installation Script
Copyright 1993 - 2007 Symantec Corporation, All Rights Reserved.


        Installing NetBackup Server Software

NOTE:  To install only NetBackup Client software locally on this machine
        or to load additional UNIX client software on this server, insert
        the NetBackup UNIX Clients cdrom.

Do you wish to continue? [y,n] (y) y

NetBackup installs to the running root environment, by default.

Are you installing to the running root environment? [y,n] (y) y

Processing package instance from solaris>

NetBackup and Media Manager
(sparc) 6.5,REV=2007.07.24.02.54
Copyright 1993 - 2007 Symantec Corporation, All Rights Reserved.

        NetBackup and Media Manager binaries will be installed in
        /opt/openv

        and a link will be created from /usr/openv
        to /opt/openv, if it does not exist.

        Is this okay? (y) [y,n,?,q]
        NetBackup and Media Manager 6.5 will be installed.

Using as the package base directory.
## Processing package information.
## Processing system information.
## Verifying disk space requirements.
## Checking for conflicts with packages already installed.

Installing NetBackup and Media Manager as

## Executing preinstall script.

    Creating /opt/openv.

    Creating link from /usr/openv to /opt/openv.

## Installing part 1 of 1.
/opt/openv/NB-Java.tar.Z
/opt/openv/db/bin/create_nbdb
/opt/openv/db/bin/nbdb_admin
/opt/openv/db/bin/nbdb_backup
/opt/openv/db/bin/nbdb_move
/opt/openv/db/bin/nbdb_ping
/opt/openv/db/bin/nbdb_restore
/opt/openv/db/bin/nbdb_unload
/opt/openv/db/bin/nbdb_upgrade
/opt/openv/db/bin/nbdbms_server_install
/opt/openv/db/bin/nbdbms_start_server
/opt/openv/db/bin/vxdbms_server.tar.Z
/opt/openv/db/lib/libsybackubr.so
/opt/openv/db/scripts/NBDB.6.0.0.0.sql
/opt/openv/db/scripts/NBDB.6.0.1.0.sql
/opt/openv/db/scripts/NBDB.6.0.2.0.sql
/opt/openv/db/scripts/NBDB.6.0.3.0.sql
/opt/openv/db/scripts/NBDB.6.0.4.0.sql
/opt/openv/db/scripts/NBDB.6.0.sql
/opt/openv/db/scripts/NBDB.downgrade.6.0.1.0.sql
/opt/openv/db/scripts/NBDB.downgrade.6.0.2.0.sql
/opt/openv/db/scripts/NBDB.downgrade.6.0.3.0.sql
/opt/openv/db/scripts/NBDB.downgrade.6.0.4.0.sql
/opt/openv/db/scripts/NBDB.downgrade.6.0.5.0.sql
/opt/openv/db/scripts/emmDeviceMapping_proc_p.sql
/opt/openv/db/scripts/emmGetNextRobotIndex_proc_p.sql
/opt/openv/db/scripts/emmMachineDeviceConnection_proc_p.sql
/opt/openv/db/scripts/emmMediaRule_proc_p.sql
/opt/openv/db/scripts/emmStu_proc_p.sql
/opt/openv/db/scripts/emm_asa_defaults.sql
/opt/openv/db/scripts/emm_asa_schema.sql
/opt/openv/db/scripts/emmproc_p.sql
/opt/openv/db/scripts/rb_asa_schema.sql
/opt/openv/lib/libAsyncEventService.so
/opt/openv/lib/libNBNosService.so
/opt/openv/lib/libVbp.so
/opt/openv/lib/libVbpMT.so
/opt/openv/lib/libVcnbac.so
/opt/openv/lib/libVcnbacST.so
/opt/openv/lib/libVcom.so
/opt/openv/lib/libVcomMT.so
/opt/openv/lib/libVdb.so
/opt/openv/lib/libVdbMT.so
/opt/openv/lib/libVdiskmediaid.so
/opt/openv/lib/libVdiskmediaidST.so
/opt/openv/lib/libVdsm.so
/opt/openv/lib/libVdsmST.so
/opt/openv/lib/libVemm.so
/opt/openv/lib/libVemmMT.so
/opt/openv/lib/libVlicense.so
/opt/openv/lib/libVlicenseMT.so
/opt/openv/lib/libVnbaz.so
/opt/openv/lib/libVnbazST.so
/opt/openv/lib/libbasictemplate.so
/opt/openv/lib/libcatalog.so
/opt/openv/lib/libicudt18b.so
/opt/openv/lib/libmgmtsvc.so
/opt/openv/lib/libsfr.so
/opt/openv/lib/libsth.so
/opt/openv/lib/libsthMT.so
/opt/openv/lib/libsthtar.so
/opt/openv/lib/libsthtarST.so
/opt/openv/lib/libsts.so
/opt/openv/lib/libstsMT.so
/opt/openv/lib/libstsemm.so
/opt/openv/lib/libstsemmMT.so
/opt/openv/lib/libstseventservice.so
/opt/openv/lib/libstsimage.so
/opt/openv/lib/libstsimageMT.so
/opt/openv/lib/libstspiarraydisk.so
/opt/openv/lib/libstspiarraydiskMT.so
/opt/openv/lib/libstspibasicdisk.so
/opt/openv/lib/libstspibasicdiskMT.so
/opt/openv/lib/libstspinearstore.so
/opt/openv/lib/libstspinearstoreMT.so
/opt/openv/lib/libstspiproxyMT.so
/opt/openv/lib/libstsproxyMT.so
/opt/openv/lib/libstsrc.so
/opt/openv/lib/libstsrcMT.so
/opt/openv/lib/libstsutil.so
/opt/openv/lib/libstsutilMT.so
/opt/openv/lib/libvrtssal_api.so
/opt/openv/lib/libvxPBXCommonST.so
/opt/openv/lib/libvxPBXIOPST.so
/opt/openv/lib/libvxPBXST.so
/opt/openv/lib/libvxPBXVxSSST.so
/opt/openv/lib/libvxSigComp2.so
/opt/openv/lib/libvxSigComp2ST.so
/opt/openv/lib/libvxSigFCL2.so
/opt/openv/lib/libvxSigFCL2ST.so
/opt/openv/lib/libvxSigSchedule2.so
/opt/openv/lib/libvxSigSchedule2ST.so
/opt/openv/lib/libvxTAOST.so.3
/opt/openv/lib/libvxTAO_BiDirGIOPST.so.3
/opt/openv/lib/libvxTAO_DynamicInterface.so.3
/opt/openv/lib/libvxTAO_IORTableST.so.3
/opt/openv/lib/libvxTAO_MessagingST.so.3
/opt/openv/lib/libvxTAO_PortableServerST.so.3
/opt/openv/lib/libvxTAO_SecurityST.so.3
/opt/openv/lib/libvxUCS4_UTF16.so.3
/opt/openv/lib/libvxVxSSIOPST.so
/opt/openv/man/man1/bp.1
/opt/openv/man/man1/bparchive.1
/opt/openv/man/man1/bpbackup.1
/opt/openv/man/man1/bpkeyfile.1
/opt/openv/man/man1/bplist.1
/opt/openv/man/man1/bprestore.1
/opt/openv/man/man1/jbpSA.1
/opt/openv/man/man1/tpreq.1
/opt/openv/man/man1/tpunmount.1
/opt/openv/man/man1/vxlogview.1
/opt/openv/man/man1m/acsd.1m
/opt/openv/man/man1m/backupdbtrace.1m
/opt/openv/man/man1m/backuptrace.1m
/opt/openv/man/man1m/bmrc.1m
/opt/openv/man/man1m/bmrconfig.1m
/opt/openv/man/man1m/bmrepadm.1m
/opt/openv/man/man1m/bmrprep.1m
/opt/openv/man/man1m/bmrs.1m
/opt/openv/man/man1m/bmrsrtadm.1m
/opt/openv/man/man1m/bpSALinfo.1m
/opt/openv/man/man1m/bpadm.1m
/opt/openv/man/man1m/bpbackupdb.1m
/opt/openv/man/man1m/bpcatarc.1m
/opt/openv/man/man1m/bpcatlist.1m
/opt/openv/man/man1m/bpcatres.1m
/opt/openv/man/man1m/bpcatrm.1m
/opt/openv/man/man1m/bpcd.1m
/opt/openv/man/man1m/bpchangeprimary.1m
/opt/openv/man/man1m/bpclient.1m
/opt/openv/man/man1m/bpclntcmd.1m
/opt/openv/man/man1m/bpcompatd.1m
/opt/openv/man/man1m/bpconfig.1m
/opt/openv/man/man1m/bpdbjobs.1m
/opt/openv/man/man1m/bpdbm.1m
/opt/openv/man/man1m/bpdgclone.1m
/opt/openv/man/man1m/bpduplicate.1m
/opt/openv/man/man1m/bperror.1m
/opt/openv/man/man1m/bpexpdate.1m
/opt/openv/man/man1m/bpfis.1m
/opt/openv/man/man1m/bpgetconfig.1m
/opt/openv/man/man1m/bpgetdebuglog.1m
/opt/openv/man/man1m/bpimage.1m
/opt/openv/man/man1m/bpimagelist.1m
/opt/openv/man/man1m/bpimmedia.1m
/opt/openv/man/man1m/bpimport.1m
/opt/openv/man/man1m/bpinst.1m
/opt/openv/man/man1m/bpkeyutil.1m
/opt/openv/man/man1m/bplabel.1m
/opt/openv/man/man1m/bpmedia.1m
/opt/openv/man/man1m/bpmedialist.1m
/opt/openv/man/man1m/bpminlicense.1m
/opt/openv/man/man1m/bpmoverinfo.1m
/opt/openv/man/man1m/bpnbat.1m
/opt/openv/man/man1m/bpnbaz.1m
/opt/openv/man/man1m/bppficorr.1m
/opt/openv/man/man1m/bpplclients.1m
/opt/openv/man/man1m/bppldelete.1m
/opt/openv/man/man1m/bpplinclude.1m
/opt/openv/man/man1m/bpplinfo.1m
/opt/openv/man/man1m/bppllist.1m
/opt/openv/man/man1m/bpplsched.1m
/opt/openv/man/man1m/bpplschedrep.1m
/opt/openv/man/man1m/bppolicynew.1m
/opt/openv/man/man1m/bpps.1m
/opt/openv/man/man1m/bprd.1m
/opt/openv/man/man1m/bprecover.1m
/opt/openv/man/man1m/bpschedule.1m
/opt/openv/man/man1m/bpschedulerep.1m
/opt/openv/man/man1m/bpsetconfig.1m
/opt/openv/man/man1m/bpstsinfo.1m
/opt/openv/man/man1m/bpstuadd.1m
/opt/openv/man/man1m/bpstudel.1m
/opt/openv/man/man1m/bpstulist.1m
/opt/openv/man/man1m/bpsturep.1m
/opt/openv/man/man1m/bptestbpcd.1m
/opt/openv/man/man1m/bptpcinfo.1m
/opt/openv/man/man1m/bpverify.1m
/opt/openv/man/man1m/cat_convert.1m
/opt/openv/man/man1m/create_nbdb.1m
/opt/openv/man/man1m/duplicatetrace.1m
/opt/openv/man/man1m/importtrace.1m
/opt/openv/man/man1m/jnbSA.1m
/opt/openv/man/man1m/ltid.1m
/opt/openv/man/man1m/nbdb_admin.1m
/opt/openv/man/man1m/nbdb_backup.1m
/opt/openv/man/man1m/nbdb_move.1m
/opt/openv/man/man1m/nbdb_ping.1m
/opt/openv/man/man1m/nbdb_restore.1m
/opt/openv/man/man1m/nbdb_unload.1m
/opt/openv/man/man1m/nbdbms_start_server.1m
/opt/openv/man/man1m/nbdbms_start_stop.1m
/opt/openv/man/man1m/nbdc.1m
/opt/openv/man/man1m/nbdelete.1m
/opt/openv/man/man1m/nbdevconfig.1m
/opt/openv/man/man1m/nbdevquery.1m
/opt/openv/man/man1m/nbemm.1m
/opt/openv/man/man1m/nbemmcmd.1m
/opt/openv/man/man1m/nbexecute.1m
/opt/openv/man/man1m/nbfirescan.1m
/opt/openv/man/man1m/nbftadm.1m
/opt/openv/man/man1m/nbftconfig.1m
/opt/openv/man/man1m/nbhba.1m
/opt/openv/man/man1m/nbjm.1m
/opt/openv/man/man1m/nbpem.1m
/opt/openv/man/man1m/nbpemreq.1m
/opt/openv/man/man1m/nbpushdata.1m
/opt/openv/man/man1m/nbrb.1m
/opt/openv/man/man1m/nbshareddisk.1m
/opt/openv/man/man1m/nbstl.1m
/opt/openv/man/man1m/nbstlutil.1m
/opt/openv/man/man1m/nbsu.1m
/opt/openv/man/man1m/nbsvrgrp.1m
/opt/openv/man/man1m/odld.1m
/opt/openv/man/man1m/restoretrace.1m
/opt/openv/man/man1m/set_ndmp_attr.1m
/opt/openv/man/man1m/tl4d.1m
/opt/openv/man/man1m/tl8cd.1m
/opt/openv/man/man1m/tl8d.1m
/opt/openv/man/man1m/tldcd.1m
/opt/openv/man/man1m/tldd.1m
/opt/openv/man/man1m/tlhcd.1m
/opt/openv/man/man1m/tlhd.1m
/opt/openv/man/man1m/tlmd.1m
/opt/openv/man/man1m/tpautoconf.1m
/opt/openv/man/man1m/tpclean.1m
/opt/openv/man/man1m/tpconfig.1m
/opt/openv/man/man1m/tpext.1m
/opt/openv/man/man1m/tpformat.1m
/opt/openv/man/man1m/tshd.1m
/opt/openv/man/man1m/verifytrace.1m
/opt/openv/man/man1m/vltadm.1m
/opt/openv/man/man1m/vltcontainers.1m
/opt/openv/man/man1m/vlteject.1m
/opt/openv/man/man1m/vltinject.1m
/opt/openv/man/man1m/vltoffsitemedia.1m
/opt/openv/man/man1m/vltopmenu.1m
/opt/openv/man/man1m/vltrun.1m
/opt/openv/man/man1m/vmadd.1m
/opt/openv/man/man1m/vmadm.1m
/opt/openv/man/man1m/vmchange.1m
/opt/openv/man/man1m/vmcheckxxx.1m
/opt/openv/man/man1m/vmd.1m
/opt/openv/man/man1m/vmdelete.1m
/opt/openv/man/man1m/vmoprcmd.1m
/opt/openv/man/man1m/vmphyinv.1m
/opt/openv/man/man1m/vmpool.1m
/opt/openv/man/man1m/vmquery.1m
/opt/openv/man/man1m/vmrule.1m
/opt/openv/man/man1m/vmupdate.1m
/opt/openv/man/man1m/vxlogcfg.1m
/opt/openv/man/man1m/vxlogmgr.1m
/opt/openv/msg/C/netbackup/TrbMsgs
/opt/openv/netbackup/bin/add_media_server
/opt/openv/netbackup/bin/add_media_server_on_clients
/opt/openv/netbackup/bin/admincmd/backupdbtrace
/opt/openv/netbackup/bin/admincmd/backuptrace
/opt/openv/netbackup/bin/admincmd/bpSALinfo
/opt/openv/netbackup/bin/admincmd/bpauthorize
/opt/openv/netbackup/bin/admincmd/bpauthsync
/opt/openv/netbackup/bin/admincmd/bpbackupdb
/opt/openv/netbackup/bin/admincmd/bpcatarc
/opt/openv/netbackup/bin/admincmd/bpcatlist
/opt/openv/netbackup/bin/admincmd/bpcatres
/opt/openv/netbackup/bin/admincmd/bpcatrm
/opt/openv/netbackup/bin/admincmd/bpccname
/opt/openv/netbackup/bin/admincmd/bpchangeprimary
/opt/openv/netbackup/bin/admincmd/bpclient
/opt/openv/netbackup/bin/admincmd/bpconfig
/opt/openv/netbackup/bin/admincmd/bpcounts
/opt/openv/netbackup/bin/admincmd/bpcoverage
/opt/openv/netbackup/bin/admincmd/bpdbjobs
/opt/openv/netbackup/bin/admincmd/bpdrfiles
/opt/openv/netbackup/bin/admincmd/bpduplicate
/opt/openv/netbackup/bin/admincmd/bperror
/opt/openv/netbackup/bin/admincmd/bpexpdate
/opt/openv/netbackup/bin/admincmd/bpflist
/opt/openv/netbackup/bin/admincmd/bpfrag
/opt/openv/netbackup/bin/admincmd/bpgetconfig
/opt/openv/netbackup/bin/admincmd/bpgetdebuglog
/opt/openv/netbackup/bin/admincmd/bpgethost
/opt/openv/netbackup/bin/admincmd/bpgetmedia
/opt/openv/netbackup/bin/admincmd/bpimage
/opt/openv/netbackup/bin/admincmd/bpimagelist
/opt/openv/netbackup/bin/admincmd/bpimmedia
/opt/openv/netbackup/bin/admincmd/bpimport
/opt/openv/netbackup/bin/admincmd/bplabel
/opt/openv/netbackup/bin/admincmd/bplicense
/opt/openv/netbackup/bin/admincmd/bplocaladdrs
/opt/openv/netbackup/bin/admincmd/bpmedia
/opt/openv/netbackup/bin/admincmd/bpmedialist
/opt/openv/netbackup/bin/admincmd/bpminlicense
/opt/openv/netbackup/bin/admincmd/bpmoverinfo
/opt/openv/netbackup/bin/admincmd/bpnbaz
/opt/openv/netbackup/bin/admincmd/bppficorr
/opt/openv/netbackup/bin/admincmd/bpplcatdrinfo
/opt/openv/netbackup/bin/admincmd/bpplclients
/opt/openv/netbackup/bin/admincmd/bppldelete
/opt/openv/netbackup/bin/admincmd/bpplinclude
/opt/openv/netbackup/bin/admincmd/bpplinfo
/opt/openv/netbackup/bin/admincmd/bppllist
/opt/openv/netbackup/bin/admincmd/bpplsched
/opt/openv/netbackup/bin/admincmd/bpplschedrep
/opt/openv/netbackup/bin/admincmd/bpplschedwin
/opt/openv/netbackup/bin/admincmd/bpplvalid
/opt/openv/netbackup/bin/admincmd/bppolicynew
/opt/openv/netbackup/bin/admincmd/bprdreq
/opt/openv/netbackup/bin/admincmd/bprecover
/opt/openv/netbackup/bin/admincmd/bpretlevel
/opt/openv/netbackup/bin/admincmd/bprsh
/opt/openv/netbackup/bin/admincmd/bpschedule
/opt/openv/netbackup/bin/admincmd/bpschedulerep
/opt/openv/netbackup/bin/admincmd/bpsetconfig
/opt/openv/netbackup/bin/admincmd/bpsnapconfig
/opt/openv/netbackup/bin/admincmd/bpstsinfo
/opt/openv/netbackup/bin/admincmd/bpstuadd
/opt/openv/netbackup/bin/admincmd/bpstudel
/opt/openv/netbackup/bin/admincmd/bpstulist
/opt/openv/netbackup/bin/admincmd/bpsturep
/opt/openv/netbackup/bin/admincmd/bpsyncinfo
/opt/openv/netbackup/bin/admincmd/bptestbpcd
/opt/openv/netbackup/bin/admincmd/bpuser
/opt/openv/netbackup/bin/admincmd/bpverify
/opt/openv/netbackup/bin/admincmd/bpversion
/opt/openv/netbackup/bin/admincmd/bpversion_update
/opt/openv/netbackup/bin/admincmd/duplicatetrace
/opt/openv/netbackup/bin/admincmd/get_license_key
/opt/openv/netbackup/bin/admincmd/importtrace
/opt/openv/netbackup/bin/admincmd/nb_updatedssu
/opt/openv/netbackup/bin/admincmd/nbdc
/opt/openv/netbackup/bin/admincmd/nbdelete
/opt/openv/netbackup/bin/admincmd/nbdevconfig
/opt/openv/netbackup/bin/admincmd/nbdevquery
/opt/openv/netbackup/bin/admincmd/nbemmcmd
/opt/openv/netbackup/bin/admincmd/nbexecute
/opt/openv/netbackup/bin/admincmd/nbftconfig
/opt/openv/netbackup/bin/admincmd/nbftsrv_config
/opt/openv/netbackup/bin/admincmd/nbhba
/opt/openv/netbackup/bin/admincmd/nbjmreq
/opt/openv/netbackup/bin/admincmd/nbpemreq
/opt/openv/netbackup/bin/admincmd/nbproxyreq
/opt/openv/netbackup/bin/admincmd/nbrbutil
/opt/openv/netbackup/bin/admincmd/nbshareddisk
/opt/openv/netbackup/bin/admincmd/nbstl
/opt/openv/netbackup/bin/admincmd/nbstlutil
/opt/openv/netbackup/bin/admincmd/nbsvrgrp
/opt/openv/netbackup/bin/admincmd/restoretrace
/opt/openv/netbackup/bin/admincmd/verifytrace
/opt/openv/netbackup/bin/backup_exit_notify
/opt/openv/netbackup/bin/backup_notify
/opt/openv/netbackup/bin/bpadm
/opt/openv/netbackup/bin/bpbrm
/opt/openv/netbackup/bin/bpbrmds
/opt/openv/netbackup/bin/bpclusterutil
/opt/openv/netbackup/bin/bpcompatd
/opt/openv/netbackup/bin/bpdbm
/opt/openv/netbackup/bin/bpdm
/opt/openv/netbackup/bin/bpinst
/opt/openv/netbackup/bin/bpjava-susvc
/opt/openv/netbackup/bin/bpjobd
/opt/openv/netbackup/bin/bprd
/opt/openv/netbackup/bin/bpsynth
/opt/openv/netbackup/bin/bptm
/opt/openv/netbackup/bin/cat_convert
/opt/openv/netbackup/bin/cluster/cluster_active
/opt/openv/netbackup/bin/cluster/cluster_config
/opt/openv/netbackup/bin/cluster/cluster_update
/opt/openv/netbackup/bin/cluster/cluster_upgrade
/opt/openv/netbackup/bin/cluster/suncluster/gethostnames
/opt/openv/netbackup/bin/cluster/suncluster/gettime
/opt/openv/netbackup/bin/cluster/suncluster/hasp_check
/opt/openv/netbackup/bin/cluster/suncluster/scnb.VRTS
/opt/openv/netbackup/bin/cluster/suncluster/scnb.conf
/opt/openv/netbackup/bin/cluster/suncluster/scnb_config
/opt/openv/netbackup/bin/cluster/suncluster/scnb_mon_check
/opt/openv/netbackup/bin/cluster/suncluster/scnb_mon_start
/opt/openv/netbackup/bin/cluster/suncluster/scnb_mon_stop
/opt/openv/netbackup/bin/cluster/suncluster/scnb_probe
/opt/openv/netbackup/bin/cluster/suncluster/scnb_probe_usr
/opt/openv/netbackup/bin/cluster/suncluster/scnb_remove
/opt/openv/netbackup/bin/cluster/suncluster/scnb_start
/opt/openv/netbackup/bin/cluster/suncluster/scnb_stop
/opt/openv/netbackup/bin/cluster/suncluster/scnb_svc_start
/opt/openv/netbackup/bin/cluster/suncluster/scnb_svc_stop
/opt/openv/netbackup/bin/cluster/suncluster/scnb_update
/opt/openv/netbackup/bin/cluster/suncluster/scnb_validate
/opt/openv/netbackup/bin/cluster/suncluster/simple_probe
/opt/openv/netbackup/bin/cluster/util/cluster_add_node
/opt/openv/netbackup/bin/cluster/util/cluster_mvnbdb
/opt/openv/netbackup/bin/cluster/util/cluster_type
/opt/openv/netbackup/bin/cluster/util/logger
/opt/openv/netbackup/bin/cluster/util/monitor
/opt/openv/netbackup/bin/cluster/util/offline
/opt/openv/netbackup/bin/cluster/util/online
/opt/openv/netbackup/bin/cluster/vcs/clean
/opt/openv/netbackup/bin/cluster/vcs/info
/opt/openv/netbackup/bin/cluster/vcs/logger
/opt/openv/netbackup/bin/cluster/vcs/monitor
/opt/openv/netbackup/bin/cluster/vcs/offline
/opt/openv/netbackup/bin/cluster/vcs/online
/opt/openv/netbackup/bin/cluster/vcs/vcs_nbu_config
/opt/openv/netbackup/bin/dbbackup_notify
/opt/openv/netbackup/bin/diskfull_notify
/opt/openv/netbackup/bin/driver/ql2300_stub.5.8
/opt/openv/netbackup/bin/driver/ql2300_stub.conf
/opt/openv/netbackup/bin/driver/windrvr6.5.9
/opt/openv/netbackup/bin/driver/windrvr6.conf
/opt/openv/netbackup/bin/goodies/README
/opt/openv/netbackup/bin/goodies/README.busy_files
/opt/openv/netbackup/bin/goodies/available_media
/opt/openv/netbackup/bin/goodies/bpend_notify
/opt/openv/netbackup/bin/goodies/bpend_notify.bat
/opt/openv/netbackup/bin/goodies/bpend_notify_busy
/opt/openv/netbackup/bin/goodies/bperrcode
/opt/openv/netbackup/bin/goodies/bpplconvert
/opt/openv/netbackup/bin/goodies/bpstart_notify
/opt/openv/netbackup/bin/goodies/bpstart_notify.bat
/opt/openv/netbackup/bin/goodies/check_coverage
/opt/openv/netbackup/bin/goodies/cleanstats
/opt/openv/netbackup/bin/goodies/db2.filelist
/opt/openv/netbackup/bin/goodies/db_begin_bkup
/opt/openv/netbackup/bin/goodies/db_begin_streams
/opt/openv/netbackup/bin/goodies/db_end_bkup
/opt/openv/netbackup/bin/goodies/db_end_streams
/opt/openv/netbackup/bin/goodies/duplicate_images
/opt/openv/netbackup/bin/goodies/edit_services
/opt/openv/netbackup/bin/goodies/fimselector
/opt/openv/netbackup/bin/goodies/lotusnotes.filelist
/opt/openv/netbackup/bin/goodies/mail_bp_reports
/opt/openv/netbackup/bin/goodies/man/add_media_server_on_clients.1m
/opt/openv/netbackup/bin/goodies/man/backupdbtrace.1m
/opt/openv/netbackup/bin/goodies/man/backuptrace.1m
/opt/openv/netbackup/bin/goodies/man/bmrc.1m
/opt/openv/netbackup/bin/goodies/man/bmrconfig.1m
/opt/openv/netbackup/bin/goodies/man/bmrepadm.1m
/opt/openv/netbackup/bin/goodies/man/bmrprep.1m
/opt/openv/netbackup/bin/goodies/man/bmrs.1m
/opt/openv/netbackup/bin/goodies/man/bmrsrtadm.1m
/opt/openv/netbackup/bin/goodies/man/bp.1
/opt/openv/netbackup/bin/goodies/man/bpSALinfo.1m
/opt/openv/netbackup/bin/goodies/man/bpadm.1m
/opt/openv/netbackup/bin/goodies/man/bparchive.1
/opt/openv/netbackup/bin/goodies/man/bpbackup.1
/opt/openv/netbackup/bin/goodies/man/bpbackupdb.1m
/opt/openv/netbackup/bin/goodies/man/bpcatarc.1m
/opt/openv/netbackup/bin/goodies/man/bpcatlist.1m
/opt/openv/netbackup/bin/goodies/man/bpcatres.1m
/opt/openv/netbackup/bin/goodies/man/bpcatrm.1m
/opt/openv/netbackup/bin/goodies/man/bpcd.1m
/opt/openv/netbackup/bin/goodies/man/bpchangeprimary.1m
/opt/openv/netbackup/bin/goodies/man/bpclient.1m
/opt/openv/netbackup/bin/goodies/man/bpclntcmd.1m
/opt/openv/netbackup/bin/goodies/man/bpcompatd.1m
/opt/openv/netbackup/bin/goodies/man/bpconfig.1m
/opt/openv/netbackup/bin/goodies/man/bpdbjobs.1m
/opt/openv/netbackup/bin/goodies/man/bpdbm.1m
/opt/openv/netbackup/bin/goodies/man/bpdgclone.1m
/opt/openv/netbackup/bin/goodies/man/bpduplicate.1m
/opt/openv/netbackup/bin/goodies/man/bperror.1m
/opt/openv/netbackup/bin/goodies/man/bpexpdate.1m
/opt/openv/netbackup/bin/goodies/man/bpfis.1m
/opt/openv/netbackup/bin/goodies/man/bpgetconfig.1m
/opt/openv/netbackup/bin/goodies/man/bpgetdebuglog.1m
/opt/openv/netbackup/bin/goodies/man/bpimage.1m
/opt/openv/netbackup/bin/goodies/man/bpimagelist.1m
/opt/openv/netbackup/bin/goodies/man/bpimmedia.1m
然后,开始配置设备让主机的NBU服务器可以找到磁带库上的驱动器。(前提是SAN已经连同,光纤交换机用的是cisco 9124,关于9124配置的问题,配置相对是比较简单的(在图形界面上的配置还是比较简单的,唯一区别的是管理9124有2个界面一个是device manager,另一个是fabric manager启动的方式不一样。device manager直接通过IE浏览器就可以启动,fabric manager需要启动本地的一个程序,装好光盘的管理软件以后,就可以在你的program file下有一个cisco manager的软件在那个里面有一个fabric manager的启动程序启动就可以了。启动的时候9124需要你进行一个默认的配置,都有提示,比较简单,这里就不贴出来了。)
环境介绍机器型号SUN440.版本SunOS 5.8 Generic_117350-26 sun4u sparc SUNW,Sun-Fire-V440.由于机器是solaris8的所以,在修改st.conf等文件的时候需要重新启动这个是比较麻烦的事情还有,重新加了4G的HBA卡。重新打了新的SAN补丁包(SAN_4.4.13)否则的话在8下是看不到4G卡的。还有如果Generic的版本太低了会对NBU6.5的写造成麻烦。会变的很慢。然后,确定是否装入了 sg 驱动程序。
调用以下命令:
/usr/sbin/modinfo | grep sg
如果装入了驱动程序,输出中会包括一行与下列内容类似的信息:
141 fc580000 2d8c 116 1 sg (SCSA Generic Revision: 3.5e)
安装 sg 驱动程序

调用以下命令:
/usr/openv/volmgr/bin/driver/sg.install
安装驱动程序之后,无需重新启动系统,也无需在每次系统启动过程中或者启动以后运行 sg.install 命令。

配置 sg 和 st 驱动程序
创建 /kernel/drv/sg.conf 文件。
创建 /dev/sg 目录和 sg 节点。
将条目添加到 /etc/devlink.tab 文件。
NetBackup 还会创建可以添加到 st.conf 文件的条目。因此,您可以在安装NetBackup 之后、在其中配置设备之前添加条目(安装 NetBackup 服务器软件时,应检查安装跟踪,以确保正确配置了 sg 驱动程序)。
下列过程中的 NetBackup sg.build 脚本会创建以下文件:
/usr/openv/volmgr/bin/driver/st.conf
/usr/openv/volmgr/bin/driver/sg.conf
/usr/openv/volmgr/bin/driver/sg.links

1。 调用下面两个命令来运行 sg.build 脚本,以便创建目标 ID 和逻辑单元:
cd /usr/openv/volmgr/bin/driver
/usr/openv/volmgr/bin/sg.build all -mt target -ml lun

下面是对这些选项的描述:
all 选项创建 NetBackup st.conf、sg.conf 和 sg.links 文件并用相应的条目填充这些文件。
-mt target 选项和参数指定 SCSI 总线所使用(或者绑定到 FCP HBA)的最大目标 ID。其最大值为 126。默认情况下,适配器的 SCSI 启动程序目标 ID 为 7,因此脚本不会为目标 ID 7 创建条目。
-ml lun 选项和参数指定 SCSI 总线(或 FCP HBA)所使用的逻辑单元号的最大值。最大值为 255。
2。 用 /usr/openv/volmgr/bin/driver/st.conf 文件中的条目替换
/kernel/drv/st.conf 文件中的下列七个条目:
name="st" class="scsi" target=0 lun=0;
name="st" class="scsi" target=1 lun=0;
name="st" class="scsi" target=2 lun=0;
name="st" class="scsi" target=3 lun=0;
name="st" class="scsi" target=4 lun=0;
name="st" class="scsi" target=5 lun=0;
name="st" class="scsi" target=6 lun=0;
修改 /kernel/drv/st.conf 文件之前,应为其创建副本。可注释掉默认条
目,而不用替换它们。若要注释掉它们,请在七个默认条目的每一行的开头放
一个 # 字符。
3。 使用重新配置选项(boot -r 或 reboot -- -r)重新启动系统。
启动进程中,系统会查明设备 st.conf 文件中的所有目标。它应为其发现的所有设备创建设备文件。
4。 使用下面的命令验证系统是否为所有磁带设备都创建了设备节点:
ls -l /dev/rmt/*cbn

5 。通过调用下面两个命令安装新的 sg 驱动程序配置:
/usr/bin/rm -f /kernel/drv/sg.conf
/usr/openv/volmgr/bin/driver/sg.install
NetBackup sg.install 脚本:
安装和装入 sg 驱动程序。
将 /usr/openv/volmgr/bin/driver/sg.conf 文件复制到
/kernel/drv/sg.conf。
创建 /dev/sg 目录和节点。
将 /usr/openv/volmgr/bin/driver/sg.links 文件追加到
/etc/devlink.tab 文件。
6。 确保 sg 驱动程序找到所有机械手、磁带机。

st.conf 文件示例
以下 /usr/openv/volmgr/bin/driver/st.conf 文件示例显示了目标 0-15
和逻辑单元号 0-7。
name="st" class="scsi" target=0 lun=0;
name="st" class="scsi" target=0 lun=1;
name="st" class="scsi" target=0 lun=2;
name="st" class="scsi" target=0 lun=3;
name="st" class="scsi" target=0 lun=4;
name="st" class="scsi" target=0 lun=5;
name="st" class="scsi" target=0 lun=6;
name="st" class="scsi" target=0 lun=7;
name="st" class="scsi" target=1 lun=0;
name="st" class="scsi" target=1 lun=1;
name="st" class="scsi" target=1 lun=2;
.

.
name="st" class="scsi" target=15 lun=5;
name="st" class="scsi" target=15 lun=6;
name="st" class="scsi" target=15 lun=7;

sg.conf 文件示例
以下 /usr/openv/volmgr/bin/driver/sg.conf 文件示例显示了目标 0-15和逻辑单元号 0-8。它还包含三个 StorEdge Network Foundation HBA 端口的目标条目。
sg.build -mt 选项不影响 FCP 目标,但是 -ml 选项会影响它。在使用sg.build命令的时候,如果给的LUN数比较大的话,会生成很多的虚拟的一些设备出现,对系统暂时没有发现有什么影响,但是,有一个问题在运行cfgadm –a和luxadm命令的时候,输出会非常的慢,这点需要注意。
因此, sg.build 脚本为这三个端口创建了逻辑单元号 0 到 7 的条目。
name="sg" class="scsi" target=0 lun=0;
name="sg" class="scsi" target=0 lun=1;
name="sg" class="scsi" target=0 lun=2;
name="sg" class="scsi" target=0 lun=3;
name="sg" class="scsi" target=0 lun=4;
name="sg" class="scsi" target=0 lun=5;
name="sg" class="scsi" target=0 lun=6;
name="sg" class="scsi" target=0 lun=7;
name="sg" class="scsi" target=1 lun=0;
name="sg" class="scsi" target=1 lun=1;
name="sg" class="scsi" target=1 lun=2;
.

.
name="sg" class="scsi" target=15 lun=5;
name="sg" class="scsi" target=15 lun=6;
name="sg" class="scsi" target=15 lun=7;
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53c3";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53c3";
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53c6";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53c6";
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53c9";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53c9";
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53cc";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53cc";
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53b9";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53b9";
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53c3";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53c3";
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53c6";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53c6";
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53c9";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53c9";
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53cc";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53cc";
name="sg" parent="fp" target=0 lun=0 fc-port-wwn="500104f0008d53b9";
name="sg" parent="fp" target=0 lun=1 fc-port-wwn="500104f0008d53b

sg.links 文件示例
以下 /usr/openv/volmgr/bin/driver/sg.links 文件示例显示了目标 0-15和逻辑单元号 0-7。它还包含用于三个 StorEdge Network Foundation HBA 端口的条目。
检测到三个端口(用它们的全球名称标识)。因此, sg.build 脚本为这三个端口创建了逻辑单元号 0 到 7 的条目。
# begin SCSA Generic devlinks file - creates nodes in /dev/sg
type=ddi_pseudo;name=sg;addr=0,0; sg/c\N0t0l0
type=ddi_pseudo;name=sg;addr=0,1; sg/c\N0t0l1
type=ddi_pseudo;name=sg;addr=0,2; sg/c\N0t0l2
type=ddi_pseudo;name=sg;addr=0,3; sg/c\N0t0l3
type=ddi_pseudo;name=sg;addr=0,4; sg/c\N0t0l4
type=ddi_pseudo;name=sg;addr=0,5; sg/c\N0t0l5
type=ddi_pseudo;name=sg;addr=0,6; sg/c\N0t0l6
type=ddi_pseudo;name=sg;addr=0,7; sg/c\N0t0l7
type=ddi_pseudo;name=sg;addr=1,0; sg/c\N0t1l0
type=ddi_pseudo;name=sg;addr=1,1; sg/c\N0t1l1
.

.
type=ddi_pseudo;name=sg;addr=f,5; sg/c\N0t15l5
type=ddi_pseudo;name=sg;addr=f,6; sg/c\N0t15l6
type=ddi_pseudo;name=sg;addr=f,7; sg/c\N0t15l7
type=ddi_pseudo;name=sg;addr=w500104f0008d53c3,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53c3,1; sg/c\N0t\A1l1
type=ddi_pseudo;name=sg;addr=w500104f0008d53c6,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53c6,1; sg/c\N0t\A1l1
type=ddi_pseudo;name=sg;addr=w500104f0008d53c9,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53c9,1; sg/c\N0t\A1l1
type=ddi_pseudo;name=sg;addr=w500104f0008d53cc,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53cc,1; sg/c\N0t\A1l1
type=ddi_pseudo;name=sg;addr=w500104f0008d53b9,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53b9,1; sg/c\N0t\A1l1
type=ddi_pseudo;name=sg;addr=w500104f0008d53c3,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53c3,1; sg/c\N0t\A1l1
type=ddi_pseudo;name=sg;addr=w500104f0008d53c6,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53c6,1; sg/c\N0t\A1l1
type=ddi_pseudo;name=sg;addr=w500104f0008d53c9,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53c9,1; sg/c\N0t\A1l1
type=ddi_pseudo;name=sg;addr=w500104f0008d53cc,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53cc,1; sg/c\N0t\A1l1
type=ddi_pseudo;name=sg;addr=w500104f0008d53b9,0; sg/c\N0t\A1l0
type=ddi_pseudo;name=sg;addr=w500104f0008d53b9,1; sg/c\N0t\A1l1
# end SCSA devlinks

配置 SCSI 和 FCP 机械手控制

要与 SCSI 控制的机械手外围设备进行通信, NetBackup 使用 NetBackup SCSI通用 (sg) 驱动程序。
配置机械手控制之前,必须安装和配置 sg 驱动程序。Solaris 使用 sg 配置来创建机械手控制设备文件。有如果在 NetBackup 中使用设备发现,则 etBackup 会自动发现位于 /dev/sg 目录的机械手控制设备文件(进而发现设备)。如果手动在 NetBackup 中添加机械手,必须输入设备文件的路径名。
若要显示 sg 驱动程序可以使用的设备文件,请使用带 all 参数的 sgscan 命令。
sgscan 输出中的单词“Changer”标识机械手控制的设备文件。

SCSI 和 FCP 机械手控制设备文件示例
下面是主机的 sgscan all 输出示例。示例指的是这个 sgscan 输出。
# /usr/openv/volmgr/bin/sgscan all
/dev/sg/c0t6l0: Cdrom: "TOSHIBA XM-5401TASUN4XCD"
/dev/sg/c1tw500104f0008d53b9l0: Changer: "STK SL500"
/dev/sg/c1tw500104f0008d53c3l0: Tape (/dev/rmt/0): "HP Ultrium 3-SCSI"
/dev/sg/c1tw500104f0008d53c6l0: Tape (/dev/rmt/1): "HP Ultrium 3-SCSI"
/dev/sg/c1tw500104f0008d53c9l0: Tape (/dev/rmt/2): "IBM ULTRIUM-TD3"
/dev/sg/c1tw500104f0008d53ccl0: Tape (/dev/rmt/3): "IBM ULTRIUM-TD3"
/dev/sg/c2t1l0: Changer: "STK SL500"
/dev/sg/c2t2l0: Tape (/dev/rmt/22): "HP Ultrium 3-SCSI"
/dev/sg/c2t3l0: Tape (/dev/rmt/10): "HP Ultrium 3-SCSI"
/dev/sg/c2tal0: Tape (/dev/rmt/1: "IBM ULTRIUM-TD3"
/dev/sg/c2tbl0: Tape (/dev/rmt/19): "IBM ULTRIUM-TD3"
/dev/sg/c3t0l0: Disk (/dev/rdsk/c1t0d0): "FUJITSU MAV2073RCSUN72G"
/dev/sg/c3t3l0: Disk (/dev/rdsk/c1t3d0): "FUJITSU MAV2073RCSUN72G"

NetBackup 使用支持压缩、关闭时不倒带和 Berkeley 式关闭的磁带机设备文件。
这些设备文件位于 /dev/rmt 目录下,其格式如下所示:
/dev/rmt/IDcbn
其中:
ID 是逻辑驱动器号,可以通过 sgscan 命令显示该值。
c 表示压缩。
b 表示 Berkeley 式关闭。
n 表示关闭时不倒带。
如果使用 NetBackup 设备发现, NetBackup 会发现设备文件,进而发现设备。如果手动向 NetBackup 配置添加磁带机,必须指定设备文件的路径名。NetBackup 要求压缩、关闭时不倒带和 Berkeley 式关闭的设备文件。
若要显示在系统中配置的磁带设备文件,请使用带 tape 参数的 sgscan 命令,如下所示:
# /usr/openv/volmgr/bin/sgscan tape
/dev/sg/c1tw500104f0008d53c3l0: Tape (/dev/rmt/0): "HP Ultrium 3-SCSI"
/dev/sg/c1tw500104f0008d53c6l0: Tape (/dev/rmt/1): "HP Ultrium 3-SCSI"
/dev/sg/c1tw500104f0008d53c9l0: Tape (/dev/rmt/2): "IBM ULTRIUM-TD3"
/dev/sg/c1tw500104f0008d53ccl0: Tape (/dev/rmt/3): "IBM ULTRIUM-TD3"
/dev/sg/c2t2l0: Tape (/dev/rmt/22): "HP Ultrium 3-SCSI"
/dev/sg/c2t3l0: Tape (/dev/rmt/10): "HP Ultrium 3-SCSI"
/dev/sg/c2tal0: Tape (/dev/rmt/18): "IBM ULTRIUM-TD3"
/dev/sg/c2tbl0: Tape (/dev/rmt/19): "IBM ULTRIUM-TD3"

配置 SAN 客户机
NetBackup SAN 客户机使用磁带驱动程序和 SCSI 直通方法,以与 etBackup FT介质服务器进行光纤传输通信。必须配置 Solaris 操作系统,以便它能够识别
NetBackup 介质服务器上的 FT 设备。为此,请修改 /kernel/drv/st.conf 文件,如下所示:
1 找到 tape-config-list= 部分,或者创建该部分(如果不存在)。
2 将以下几行添加到 tape-config-list= 部分:
"ARCHIVE Python", "FT Pipe", "ARCH_04106";
“包含” ARCH_04106 的 ARCHIVE Python 行可能已存在于 st.conf 文件中。但是,它应以注释字符 (#) 开头。如果没有,请在现有行的开头添加一个注释字符。

3 找到以 ARCH_04106 “开头”的行,复制该行并将其粘贴到tape-config-list= 行之后。删除这一行最前面的注释字符 (#)。下面是该行的一个示例:
ARCH_04106 = 1, 0x2C, 0, 0x09639, 4, 0x00, 0x8C, 0x8c, 0x8C, 3;
(记得这里需要是必须让磁带的类型是可变长的就是第3位必须是0,否则在运行备份的时候会报错的)
修改 /kernel/drv/st.conf,以便 Solaris 能够发现两个逻辑单元号上的设备,如下所示:
1 在 st.conf 文件中找到以下行:
name="st" class="scsi" target=0 lun=0;
2 用下面的内容替换该行和目标 5 中的下列各行。这将修改 st.conf 文件,以包含对非零逻辑单元号的搜索。
name="st" class="scsi" target=0 lun=0;
name="st" class="scsi" target=0 lun=1;
name="st" class="scsi" target=1 lun=0;
name="st" class="scsi" target=1 lun=1;
name="st" class="scsi" target=2 lun=0;
name="st" class="scsi" target=2 lun=1;
name="st" class="scsi" target=3 lun=0;
name="st" class="scsi" target=3 lun=1;
name="st" class="scsi" target=4 lun=0;
name="st" class="scsi" target=4 lun=1;
name="st" class="scsi" target=5 lun=0;
name="st" class="scsi" target=5 lun=1;
name="st" parent="fp" target=0;
name="st" parent="fp" target=1;
name="st" parent="fp" target=2;
name="st" parent="fp" target=3;
name="st" parent="fp" target=4;
name="st" parent="fp" target=5;
name="st" parent="fp" target=6;

如果,你本地有磁带机的话,在NBU上是可以看到的,只要不选择使用本地的磁带机是不会造成影响的。剩下就可以在NBU中配置备份了。
阅读(3850) | 评论(0) | 转发(0) |
给主人留下些什么吧!~~