2009-07-23 18:29:16
环境Pseries AIX HACMP
问题当hacmp运行的情况下,在errpt里看到许多TS_NIM_ERROR_RDWR_E的报错:LABEL: TS_NIM_ERROR_RDWR_E IDENTIFIER: 90D3329C Class: S Type: PERM Resource Name: topsvcs Description NIM read/write error
Probable Causes Topology Services Network Interface Module (NIM) error:Read error while trying to retrieve packets Write error while trying to send packets
Failure Causes Lack of 'mbufs' Network is down I/O errors while accessing heartbeating device Remote side is not present
Detailed DataInterface name tty0
1.停止HACMP服务smit clstop-->graceful 2.检查串口心跳设备tty0是否被别的进程占用fuser /dev/tty0-->kill any process using tty0 3.检查两个节点的tty0的联通性cat /dev/tty0"-->ok 4.改变tty0的baud rate为9600smit chtty-->everything is correct for tty0 on both nodes
5.将hacmp心跳网络的parameter改为9600smit hacmp?extended config?topology config?network module? Custom Values?Parameter=9600
6. 如果上述方法还是不能解决问题,如果节点间有复用器的话,请确保复用器的设置正常
上一篇:RSCT 资源管理及监控
下一篇:在HACMP v5.x中使用磁盘心跳网络