昨日正在倒弄lparmonv2,却发现2台570上有个硬件报警错误,详细内容如下:
ccdd@root[/>]errpt
IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION
8B88700A 0214155608 T H hdisk3 CACHE BATTERY CHARGE BELOW 87.5%
8B88700A 0214155608 T H hdisk2 CACHE BATTERY CHARGE BELOW 87.5%
ccdd@root[/>]errpt -aj 8B88700A|more
---------------------------------------------------------------------------
LABEL: FCP_ARRAY_ERR16
IDENTIFIER: 8B88700A
Date/Time: Thu Feb 14 15:56:15 BEIS
Sequence Number: 2630
Machine Id: 00C4BD5E4C00
Node Id: ccdd
Class: H
Type: TEMP
Resource Name: hdisk3
Resource Class: disk
Resource Type: array
Location: U7879.001.DQD0GG8-P1-C5-T1-W200700A0B817C7D5-L1000000000000
Description
CACHE BATTERY CHARGE BELOW 87.5%
Probable Causes
CONTROLLER CACHE BATTERY
WRITE CACHE HAS BEEN DISABLED
Failure Causes
CONTROLLER CACHE BATTERY
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
MONITOR BATTERY STATUS.
Detail Data
SENSE DATA
0600 0308 0000 FF00 0000 0004 0000 0000 0000 0000 0000 0000 0000 0000 7000 0600
0000 0098 0000 0000 3FD9 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0008 3700 0000 0000 0000 0000 0000 0000 0000 3154 3530 3634 3931 3332 2020 2020
2020 0612 0300 0001 0000 FF00 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0001 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 081F C66B 3032 3134 3038 2F30 3031 3633 3800 0000 0000 0000 0000 0000
0000 0000 2226 1000 F305 2503 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000
---------------------------------------------------------------------------
LABEL: FCP_ARRAY_ERR16
IDENTIFIER: 8B88700A
Date/Time: Thu Feb 14 15:56:11 BEIS
Sequence Number: 2629
Machine Id: 00C4BD5E4C00
Node Id: ccdd
Class: H
Type: TEMP
Resource Name: hdisk2
Resource Class: disk
Resource Type: array
Location: U7879.001.DQD0GG8-P1-C5-T1-W200700A0B817C7D5-L0
Description
CACHE BATTERY CHARGE BELOW 87.5%
Probable Causes
CONTROLLER CACHE BATTERY
WRITE CACHE HAS BEEN DISABLED
Failure Causes
CONTROLLER CACHE BATTERY
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
MONITOR BATTERY STATUS.
Detail Data
SENSE DATA
0600 0308 0000 FF00 0000 0004 0000 0000 0000 0000 0000 0000 0000 0000 7000 0600
0000 0098 0000 0000 3FD9 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0008 3700 0000 0000 0000 0000 0000 0000 0000 3154 3530 3634 3637 3134 2020 2020
2020 0612 0300 0000 0000 FF00 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0001 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 4B51 85CE 3032 3134 3038 2F30 3031 3631 3900 0000 0000 0000 0000 0000
0000 0000 2226 1000 F305 2503 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000
接着做diag又没提示什么问题,用Storage Manager 9 Client连接到DS4300里,找到错误是CONTROLLER CACHE BATTERY使用快过期了,以前也换过别的存储上的电池,今天早上报修了,